1. UZI-TDD-N38-2570-2620M-5W-120105-48VGaN-BPF-FB
Uziwave
| Availability: | |
|---|---|
| Quantity: | |
dopts 5G TDD N77 band (3800-4200MHz) design with GaN material and 48V±5% (45.6-50.4V) power supply, integrated cavity filter and dedicated DPD coupling port (FB port), supporting 100M source bandwidth and 10-100MHz carrier bandwidth for wideband 5G signal transmission.
Items: | Uplink (UL) & Downlink (UL) Specifications: |
|---|---|
Frequency Range: | |
Carrier Bandwidth: | |
Max Gain: | |
Maximum Output Power: | |
Maximum Input Level: | |
Gain Adjustment Range: | |
ALC Range: | |
Gain Flatness: | |
In-Band Ripple: | |
Noise Figure: | |
Transmit-Receive Leakage Power: | ≤-18dBm (Pout= 37.5dBm) |
Tx-Rx Isolation: | ≥55dBc |
TDD Switch Switching Time: | ≤2.5μs (PA to LNA), ≤2.5μs (LNA to PA) |
ACPR(20 MHz source bandwidth): | ≤−38 dBc (without DPD)≤−50 dBc (with DPD) |
EVM: | ≤3.5% (Peak-to-Average Power Ratio 10.0dB) |
VSWR: | |
FB Port (DPD) Coupling Factor: | 37.5±2 dB |
FB Port VSWR: | ≤1.5 |
FB Port Output Power: | 0.5±2 dBm |
Thermistor Resistance: | NTC 100kΩ |
Out-of-band Spurious (Downlink): | |
Out-of-band Spurious (ANT Port): | |
Out-of-band Spurious (LNA_OUT Port): | |
Out-of-band Rejection: | |
Operating Voltage: | 48V±5% (45.6-50.4V) |
Operating Current: | ≤0.7A (Strictly no exceeding) |
Baud Rate: | 19200 |
Working Temperature: | -40~+55℃ |
Over-Temperature Protection: | Alarm and shutdown at +85℃, resume operation at 65℃ |
Transmit-Receive Wire Control Interface: | CMOS3.3V |
Connectors: | 4 total (including FB coupling port): ANT uses SMA, others use IPEX |
Monitoring Functions: | Interface: RS485 communicationNote: All monitoring functions must be fully tested. |
Mechanical Dimensions: | 120 × 105 × 36.3 mm |
Appearance Inspection: |
Cover silk screen consistent with indicators
Labels neat and correct
PA cover and shell neat without scratches
Configuration: PA on/off control, gain setting
Query: Module status (PA status, over-power alarm, over-temperature alarm), PA temperature, VSWR, PA ATT value, forward power detection
Over-power Alarm: Triggered when power exceeds max output power +2 dB
Over-temperature Alarm: Recommended threshold +85 °C; alarm & PA shutdown above +85 °C, auto-recovery at +65 °C
PA Temperature Detection: Range ≥ −25 °C to +85 °C, accuracy ±3 °C
Forward Power Detection (45 dBm to 20 dBm): Range >20 dB, accuracy <±1 dB
Reverse Power Detection (45 dBm to 20 dBm): Range >25 dB, accuracy <±1.5 dB
Supply Voltage Detection: Accuracy ≤±1 V (measured at 48V input)
Current Detection Accuracy: ≤±200 mA (Tx mode, no input); ≤±200 mA (Tx mode, Pout = 37.5 dBm)
Temperature Verification: ±3 °C; thermistor resistance to GND (measured by multimeter): 50 kΩ–150 kΩ
VSWR Detection: When PA output ≥20 dBm with proper cable connection, actual VSWR shall be readable via software
VSWR Alarm: ANT port open with PA output ≥20 dBm → detected VSWR ≥3.0 and VSWR alarm asserted
1–2290 MHz: 65 dB
2290–2420 MHz: 65 dB
2420–2500 MHz: 60 dB
2500–2550 MHz: 55 dB
2550–2560 MHz: 22 dB (−40 °C to 65 °C)
2630–2640 MHz: 22 dB (−40 °C to 65 °C)
2640–2670 MHz: 55 dB
2670–3300 MHz: 68 dB
3300–4200 MHz: 74 dB
4200–5925 MHz: 74 dB
5925–7200 MHz: 74 dB
7.2–10 GHz: 64 dB
10–15 GHz: 44 dB
30 MHz–1 GHz: ≤−80 dBm/100 kHz
1 GHz–6 GHz: ≤−70 dBm/1 MHz
6 GHz–12.75 GHz: ≤−60 dBm/1 MHz
12.75 GHz–24.5 GHz: ≤−60 dBm/1 MHz
3.3 GHz–3.8 GHz: ≤−91 dBm/100 kHz
30MHz~1GHz@≤-57dBm/100kHz
1GHz~12.75GHz@≤-47dBm/1MHz
12.75~24.5GHz@≤-47dBm/1MHz
9 kHz–150 kHz: ≤−36 dBm/1 kHz
150 kHz–30 MHz: ≤−36 dBm/10 kHz
30 MHz–1 GHz: ≤−36 dBm/100 kHz
1 GHz–2.56 GHz: ≤−34 dBm/1 MHz
2.63 GHz–12.75 GHz: ≤−34 dBm/1 MHz
≤2.0 (Uplink),
≤1.5 (Downlink)
UL:≤5dB
DL:NONE
UL:≤1.8dB
DL:≤2dB
ATT10dB: ≤±1dB
ATT20dB: ≤±1dB
ATT25dB: ≤±1.5dB
UL:NONE
UL:NONE
DL:≥10dB
UL:NONE
DL:≥25dB
UL:+10dBm
DL:+10dBm
UL:Non-controlled (P1dB=+10dBm)
ALC regulated at 42.5 dBm (with cavity filter); Test at 37.5 dBm
UL:18±2dB
DL:45±2dB
UL:5–40 MHz
DL:5–40 MHz
UL:2570–2620 MHz
DL:2570–2620 MHz
Firmware compliant with 5G telecommunication standards
Source signal bandwidth: 100 MHz
48V supply, GaN (Gallium Nitride) technology
Equipped with DPD coupling port (FB port)
Integrated cavity filter
state: Default to OFF
UZI-TDD-N38-2570-2620M-5W-120105-48VGaN-BPF-FB
Adopts 5G TDD N38 band design with GaN material and 48V±5% power supply, integrated cavity filter and dedicated DPD coupling port (FB port), supporting 100M source bandwidth and 5-40MHz carrier bandwidth.
Realizes high-performance UL/DL dual-channel transmission, with DL ALC stabilized at 42.5dBm (tested at 37.5dBm), Tx-Rx isolation ≥55dBc and TDD switching time ≤2.5μs, meeting customer special requirements for fast switching.
Equipped with comprehensive RS485 monitoring & protection functions, including over-power/over-temperature/VSWR alarm, precise detection of power/current/temperature/VSWR, and over-temperature auto-shutdown at +85℃ (recovery at 65℃).
Features excellent RF performance: DL EVM ≤3.5% (@PAR 10dB), in-band ripple ≤2.0dB, out-of-band spurious emission suppression compliant with strict standards, and FB port coupling degree 37.5±2dB with stable output.
Compact mechanical design (120×105×36.3mm) with 4 connectors (ANT-SMA, others-IPEX), CMOS3.3V Tx-Rx control interface and NTC 100kΩ thermistor, suitable for high-reliability industrial applications (-40~+55℃ working temperature).
Realizes high-performance UL/DL dual-channel work, with DL output power ALC-stabilized at 42.5dBm (tested at 35.8dBm), UL P1dB at 10-17dBm, Tx-Rx isolation ≥55dBc and TDD switching time ≤2.5μs, meeting customer’s fast-switching special requirements.
Complies with strict RF performance standards: ACPR tested and qualified for both 20M/100M source bandwidth (20M: ≤-38dBc without DPD/≤-50dBc with DPD; 100M: ≤-36dBc without DPD/≤-50dBc with DPD), EVM ≤3.5% (@PAR 10dB), and in-band ripple ≤2.5dB for stable and high-quality signal output.
Equipped with comprehensive RS485 monitoring and multi-protection functions, including over-power/over-temperature/VSWR alarm, precise detection of power/current/voltage/temperature, over-temperature auto-shutdown at +85℃ (recovery at 65℃), and strict VSWR detection and protection to avoid instrument damage.
Features excellent out-of-band performance with high suppression capability (up to ≥74dBc in 6000-7200MHz band) and compliant spurious emissions for ANT/LNA_OUT ports; compact size (120×105×36.3mm) with 4 connectors (ANT-SMA, others-IPEX), CMOS3.3V Tx-Rx control interface, and wide working temperature range (-40~+55℃) for easy integration and industrial-grade reliability.
UZI-TDD-N77-3800-4200M-4W-120105-48VGaN-BPF-FB
Items: | Uplink (UL) & Downlink (UL) Specifications: |
|---|---|
Frequency Range: |
|
Carrier Bandwidth: |
|
Max Gain: |
|
Maximum Output Power: |
|
Maximum Input Level: |
|
Gain Adjustment Range: |
|
ALC Range: |
|
Gain Flatness: |
|
In-Band Ripple: |
|
Noise Figure: |
|
Transmit-Receive Leakage Power: | ≤−18 dBm (@ Pout= 35.8 dBm) |
Tx-Rx Isolation: |
|
TDD Switch Switching Time: | ≤2.5μs (PA to LNA), ≤2.5μs (LNA to PA) |
ACPR(Test required for 20M/100M source bandwidth, all results must be qualified) |
|
EVM: | ≤3.5% (Peak-to-Average Power Ratio 10.0dB) |
VSWR: |
|
Feedback (FB) Port Index: |
|
Thermistor Resistance: | NTC 100kΩ |
Out-of-band Spurious (Downlink): |
|
Out-of-band Spurious (ANT Port): |
|
Out-of-band Spurious (LNA_OUT Port): |
|
Out-of-band Rejection: |
|
Operating Voltage: | 48V±5% (45.6-50.4V) |
Operating Current: | ≤0.75A (Strictly no exceeding) |
Baud Rate: | 19200 |
Working Temperature: | -40~+55℃ |
Over-Temperature Protection: | Alarm and shutdown at +85℃, resume operation at 65℃ |
Transmit-Receive Wire Control Interface: | CMOS3.3V |
Connectors: | 4 connectors in total (including FB coupling port): ANT port with SMA connector, others with IPEX connectors |
Mechanical Dimensions: | 120×105×36.3 mm |
Monitoring Functions: | Configuration: Power on/off control, gain adjustment Query: Module status (including PA status, over-power alarm, over-temperature alarm), PA temperature, VSWR value, PA ATT value, detected forward power Over-power Alarm: Alarm triggered when output power exceeds the maximum output power by +2 dB Over-temperature Alarm: Recommended threshold at +85℃; alarm and PA shutdown when detected temperature exceeds +85℃, auto-recovery at +65℃ PA Temperature Detection: Detection range covers at least -25℃~+85℃, detection accuracy ±3℃ Forward Power Detection (45dBm-20dBm): Detection range >20 dB, detection accuracy <±1 dB Reverse Power Detection (45dBm-20dBm): Detection range >25 dB, detection accuracy <±1.5 dB Voltage Detection Accuracy: ≤±1V (measured under +48V power supply) Current Detection Accuracy: ≤±200mA (Transmit mode, no input signal); ≤±200mA (Transmit mode, Pout= 37.5dBm) Temperature Detection: ±3℃ (Measure the pin-to-ground resistance with a multimeter, the measured resistance shall be within 50K-150K range) VSWR Value Detection: When PA output power ≥20dBm with normal cable connection, the software shall detect the actual VSWR value VSWR Alarm: When PA output power ≥20dBm and ANT port is open, the detected VSWR ≥3.0 and a VSWR alarm shall be generated simultaneously |
Appearance Inspection: |
|
Broadband MIMO Performance: Operates at 3550-3700MHz (N48) with 20-100MHz carrier bandwidth, supports MIMO 2T2R mode and dual uplink/downlink testing for flexible broadband application.
High Gain & Precise Power Control: Delivers 20±2dB uplink gain and 45±2dB downlink gain; downlink ALC controls 42.5dBm output with ≥25dB gain adjustment range and high adjustment accuracy for stable power output.
Superior RF Performance: Boasts NF ≤5dB (uplink), in-band ripple ≤1.8/2.0dB (UL/DL), Tx-Rx isolation ≥55dBc and EVM ≤3.5%; excellent ACPR performance for both 20M/100M bandwidth with/without DPD, meeting strict signal quality requirements.
Comprehensive Protection & Monitoring: Equipped with 85℃ overtemperature shutdown/65℃ recovery, over-power/VSWR alarm; RS485 monitoring interface supports real-time detection of power, temperature, voltage, current and VSWR with high measurement accuracy.
Stable Power Supply & Compact Design: Adopts 48V±5% (45.6-50.4V) power supply with ≤0.75A operating current; compact size 300*70*40mm, SMA (ANT) & IPEX connectors, and wide temperature adaptability (-40~+55℃) for easy deployment.
UZI-TDD-N48-3550-3700M-5W-30070QT-2T2R-48V-FB
Items: | Uplink (UL) & Downlink (UL) Specifications: |
|---|---|
Frequency Range: |
|
Carrier Bandwidth: |
|
Max Gain: |
|
Maximum Output Power: |
|
Maximum Input Level: |
|
Gain Adjustment Range: |
|
ALC Range: |
|
Gain Flatness: |
|
In-Band Ripple: |
|
Noise Figure: |
|
Transmit-Receive Leakage Power: | ≤-18dBm (Pout= 37.5dBm) |
Tx-Rx Isolation: | ≥55dBc |
Dual-channel Isolation: |
|
TDD Switch Switching Time: | ≤2.5μs (PA to LNA), ≤2.5μs (LNA to PA) |
ACPR(Test required for 20M/100M source bandwidth, all results must be qualified) |
|
EVM: | ≤3.5% (Peak-to-Average Power Ratio 10.0dB) |
VSWR: |
|
Feedback (FB) Port Index: |
|
Thermistor Resistance: | NTC 100kΩ |
Out-of-band Spurious (Downlink): |
|
Out-of-band Spurious (ANT Port): |
|
Out-of-band Spurious (LNA_OUT Port): |
|
Out-of-band Rejection: |
|
Operating Voltage: | 48V±5% (45.6-50.4V) |
Operating Current: | ≤0.75A (Strictly no exceeding) |
Baud Rate: | 19200 |
Working Temperature: | -40~+55℃ |
Over-Temperature Protection: | Alarm and shutdown at +85℃, resume operation at 65℃ |
Transmit-Receive Wire Control Interface: | CMOS3.3V |
Connectors: | SMA for ANT port, IPEX for the rest |
Monitoring Functions: | RS485 interface communication: 1) Setting: Switch, gain 2) Query: Module status (including PA status, over-power alarm, overtemperature alarm), PA temperature, VSWR value, PA ATT value, detected forward power 3) Over-power alarm: Alarm when power exceeds max output power by +2dB 4) Overtemperature alarm: Recommended threshold +85℃; alarm and PA shutdown when detected temperature exceeds +85℃, resume at +65℃ 5) PA temperature detection: Range includes -25℃~+85℃ (not limited), accuracy ±3℃ 6) Forward power detection (45dBm-20dBm): Range >20dB, accuracy <±1dB 7) Reverse power detection (45dBm-20dBm): Range >25dB, accuracy <±1.5dB 8) Voltage detection accuracy: ≤±1V (measured at +48V power supply) 9) Current detection accuracy: ≤±200mA (transmit mode, no input); ≤±200mA (transmit mode, Pout= 37.5dBm) 10) Temperature detection: ±3℃ (Measure the resistance of this pin to ground with a multimeter, the value shall be 50K-150KΩ) 11) VSWR detection: Software can detect the actual VSWR value with normal cable connection when PA output power ≥20dBm 12) VSWR alarm: Detect VSWR ≥3.0 and trigger alarm when ANT port is open with PA output power ≥20dBm |
Appearance Inspection: |
|